Rev. Col. Bras. Cir ; 46(2): e2079, 2019. tab, graf
Article in Portuguese | LILACS | ID: biblio-1003093

ABSTRACT

RESUMO Com a utilização crescente da máquina de perfusão no transplante renal, tem sido constatado que a isquemia dinâmica correlaciona-se à melhora da preservação orgânica. Nesse contexto, realizamos uma revisão sistemática que procurou avaliar a eficácia do uso de máquina de perfusão portátil (LifePort Kidney Transporter Machine®), utilizada no Brasil, comparada ao armazenamento estático, no que tange à função retardada do transplante renal de doadores com morte encefálica. Foi efetuada pesquisa bibliográfica, nas bases LILACS, MEDLINE via PubMed, Scopus, Clarivate Analytics, Cochrane Library, Embase, SciELO, além de busca manual no Google acadêmico. A revisão sistemática, finalizada em abril 2017, foi constituída somente por ensaios clínicos randomizados. Para metanálise, foram avaliadas Razão de Risco e Razão de Chance. Foram identificados 86 documentos e selecionados, ao final, dois artigos com critérios de elegibilidade para metanálise, de grupos europeus e brasileiros. Nestes, 374 rins foram alocados para a máquina de perfusão, e igual número para o armazenamento estático. A função retardada do enxerto foi constatada em 84 e 110 pacientes, respectivamente. Na metanálise, foram obtidas uma Razão de Risco de 0,7568 (p=0,0151) e uma Razão de Chance de 0,6665 (p=0,0225), ambas com intervalo de confiança de 95%. A máquina de perfusão reduziu a incidência de função retardada do enxerto de doadores com morte encefálica.


ABSTRACT With the increasing use of machine perfusion in kidney transplantation, it has been observed that dynamic ischemia correlates with the improvement of organ preservation. In this context, we performed a systematic review that aimed to evaluate the efficacy of the portable machine perfusion (LifePort Kidney Transporter Machine®), used in Brazil, compared to cold storage, regarding the delayed graft function of deceased donors with brain death. Literature search was carried out in LILACS, MEDLINE via PubMed, Scopus, Clarivate Analytics, Cochrane Library, Embase, and SciELO, as well as in Google Scholar manually. The systematic review consisted only of randomized clinical trials. For meta-analysis, relative risk and odds ratio were evaluated. Eighty-six documents were identified and two papers from European and Brazilian groups were selected at the end, with eligibility criteria for meta-analysis. In these, 374 kidneys were assigned to machine perfusion and 374 kidneys were assigned to cold storage. Delayed graft function was observed in 84 and 110 patients, respectively. In meta-analysis, a risk ratio of 0.7568 (p=0.0151) and an odds ratio of 0.6665 (p=0.0225) were obtained, both with a 95% confidence interval. Machine perfusion reduced the incidence of delayed graft function of deceased donors with brain death.


Subject(s)
Humans , Organ Preservation/methods , Perfusion/methods , Brain Death , Cold Ischemia/methods , Kidney , Organ Preservation/instrumentation , Perfusion/instrumentation , Time Factors , Pulsatile Flow , Reproducibility of Results , Risk Factors , Kidney Transplantation/methods , Delayed Graft Function
2.
J. vasc. bras ; 15(3): 205-209, jul.-set. 2016. tab, graf
Article in Portuguese | LILACS | ID: lil-797970

ABSTRACT

Resumo Contexto As cardiopatias podem causar alterações no formato das ondas da ultrassonografia vascular (UV) em vasos periféricos. Essas alterações, tipicamente bilaterais e sistêmicas, são pouco conhecidas e estudadas. Objetivo Avaliar as ondas periféricas da UV de pacientes idosos para identificar alterações decorrentes de cardiopatias. Métodos Foram estudados 183 pacientes idosos submetidos a UV periférica no ano de 2014. Resultados Foram avaliados 102 mulheres (55,7%) e 81 homens (44,3%) com idade entre 60 e 91 anos (média de 70,4±7,2 anos). Encontraram-se alterações pela UV em 84 pacientes (45,9%). Foram identificadas 138 alterações de oito dos 13 tipos descritos na literatura: arritmia, onda bisferiens de pico sistólico, baixa velocidade de pico sistólico, pulsatilidade em veias femorais, bradicardia, taquicardia, onda de pulso parvus tardus e onda de pulso alternans. Houve baixa concordância entre a presença e a não presença de alterações na UV e na avaliação cardiológica. Na análise específica das alterações, os exames tiveram uma concordância variável, que foi boa para o achado de taquicardia, moderada para arritmia e baixa para bradicardia. Não houve concordância entre a UV e os exames cardiológicos para as demais alterações. Conclusões É possível identificar determinadas alterações cardíacas em idosos por meio da análise do formato das ondas periféricas da UV. É importante reconhecer e relatar a presença dessas alterações, pela possibilidade de alertar para um diagnóstico ainda não identificado nesses pacientes. Entretanto, mais estudos são necessários para que seja definida a importância das alterações no formato das ondas Doppler periféricas no reconhecimento de cardiopatias.


Abstract Background Heart diseases can cause changes to vascular ultrasonography (VUS) waveforms in peripheral vessels. These changes are typically bilateral and systemic, they have been little studied, and little is known about them. Objective To assess peripheral VUS waveforms in elderly patients in order to identify changes caused by heart diseases. Methods During 2014, a total of 183 elderly patients were examined with peripheral VUS and the results were analyzed. Results The sample comprised 102 women (55.7%) and 81 men (44.3%) with ages ranging from 60 to 91 years (mean of 70.4±7.2 years). Abnormalities were identified in VUS waveforms in 84 patients (45.9%). A total of 138 abnormalities were identified and classified into eight of the 13 categories described in the literature, as follows: arrhythmia, systolic pulsus bisferiens, low peak systolic velocity, pulsatile flow in femoral veins, bradycardia, tachycardia, pulsus tardus et parvus and pulsus alternans. There was low agreement between presence/absence of VUS abnormalities and cardiological assessments. Analysis of specific abnormalities revealed variable levels of agreement between VUS and cardiological assessments, ranging from good for tachycardia, moderate for arrhythmia, to low for bradycardia. There was no agreement between VUS and cardiological examinations for the remaining categories of abnormalities. Conclusions Certain cardiac abnormalities can be identified in elderly patients by analysis of peripheral VUS waveforms. It is important to recognize and report the presence of these abnormalities because there is a possibility that they may serve to signal hitherto unidentified diagnoses in these patients. However, further studies are needed to determine the importance of changes to peripheral Doppler waveforms to recognition of heart diseases.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Aortic Valve Insufficiency/etiology , Heart Diseases/diagnostic imaging , Heart Diseases/mortality , Cross-Sectional Studies , Echocardiography, Doppler, Color , Heart Diseases/diagnosis
3.
Arq. bras. cardiol ; 102(3): 237-244, 03/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-705715

ABSTRACT

Fundamento: A disfunção endotelial se caracteriza por um fenômeno vascular, com importância evidente em todos os processos da aterogênese. Interessa, assim, a busca por métodos de avaliação da disfunção endotelial mais acurados, práticos e menos dispendiosos, objetivando melhoria na prevenção e tratamento das doenças ateroscleróticas. Objetivo: Verificar o potencial do índice de perfusão derivado da oximetria de pulso (IPP) como método de avaliação da disfunção endotelial em pacientes portadores de aterosclerose Métodos: Foram selecionados 18 pacientes controles e 24 pacientes portadores de doenças ateroscleróticas, em tratamento otimizado, selecionados em Unidades Básicas de Saúde. Foram avaliados os valores do IPP antes a após a aplicação de um estímulo vasodilatador dependente do endotélio - a hiperemia reativa. Também foram analisados os valores do IPP especificamente no período que possui a maior contribuição do óxido nítrico para a vasodilatação (IPP90-120). Os resultados do IPP foram discutidos, por meio da literatura, estimando o seu potencial diagnóstico e prognóstico. Resultados: A resposta vasodilatadora dependente do endotélio mensurada pelo IPP foi significantemente menor em indivíduos com aterosclerose em comparação aos controles a partir de 45 segundos após a hiperemia reativa. Foram observados, do mesmo modo, valores menores do IPP90-120 em pacientes com aterosclerose [35% (4% - 53%) vs. 73% (55% - 169%); p < 0,001]. Tais valores se mantiveram menores tanto em indivíduos masculinos quanto femininos. Conclusões: Os resultados do IPP, demonstrados na avaliação de pacientes ateroscleróticos, associados ao baixo custo da aparelhagem, tornam esse método ...


Background: Endothelial dysfunction is vascular phenomenon that plays an important role in atherosclerosis development. With the purpose of improving the prevention and treatment of atherosclerotic diseases, the searching for accurate, practical and cheaper methods for evaluating endothelial function have become of interest. Objectives: Verify the potential of Peripheral Perfusion Index from pulse oximetry (IPP) as a method of endothelial dysfunction evaluation in patients with atherosclerotic diseases. Methods: There were recruited 18 control patients and 24 patients with atherosclerotic diseases under optimized treatment, in basic health units. The values of IPP were evaluated before and after an endothelial-dependent stimulus, the reactive hyperemia. The values of IPP were also evaluated in period which the major contribution of Nitric Oxide (NO) for the vasodilation occurs (IPP90-120). The results of IPP were discussed using the literature and estimating their diagnostic and prognostic potential Results: The endothelium-dependent vasodilatory response measured by IPP was significantly lower in patients with atherosclerosis compared to control group, since 45 seconds after reactive hyperemia. Also, the values of IPP90-120 were significantly lower in patients with atherosclerosis [35% (4 - 53%) vs 73% (55 - 169%); p<0,001]. Similarly, the IPP values were lower in atherosclerosis group when it was separated by gender. Conclusion: The results of this study, in association with the low cost of pulse oximeter, suggest a good potential for IPP as an endothelial dysfunction evaluation method. New studies must be done in order to clarify this potential and possibly contribute with the prevention and treatment of atherosclerotic diseases. .


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Atherosclerosis/physiopathology , Endothelium, Vascular/physiopathology , Oximetry/methods , Pulsatile Flow/physiology , Case-Control Studies , Hemodynamics , Oximetry/instrumentation , Reference Values , Reproducibility of Results , Risk Factors , Sex Factors , Statistics, Nonparametric , Time Factors
4.
Rev. bras. cir. cardiovasc ; 24(2): 188-193, abr.-jun. 2009. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-525550

ABSTRACT

OBJETIVO: Dentre os equipamentos utilizados em circulação extracorpórea, as bombas de rolete têm grande importância, com diversos modelos disponíveis de vários fabricantes. A calibração é um fator importante nas taxas de hemólise e o seu potencial difere em cada uma delas. Pesquisadores nem sempre abordam detalhes sobre os perfis do leito rígido, supondo que as formas padronizadas de calibração garantem valores iguais e comparáveis para todos os modelos de bombas de rolete. Dispomos principalmente de dois métodos para a calibração das bombas, o que também interfere com o potencial hemolítico. Nenhum dos métodos considera as características de impulsão do fluído, definido pela forma construtiva do leito rígido. O objetivo é avaliar o perfil hidrodinâmico de três modelos de bombas de roletes disponíveis no mercado brasileiro. MÉTODOS: A oclusão dos roletes foi feita por medidas de velocidade de queda e calibração dinâmica. Foram utilizados dois diferentes diâmetros de tubos de silicone (3/8 x 1/16 e 1/2 x 3/32 polegadas). RESULTADOS: Os perfis apresentaram diferenças em suas variâncias. P<0,01 para medidas de velocidade de queda e P<0,0001 para medidas de calibração dinâmica. Foram encontradas diferenças nas variações de pressão entre as bombas analisadas (P<0,002). CONCLUSÃO: As medidas de oclusão são dependentes da forma do leito rígido e comparações envolvendo bombas de rolete devem ser feitas com cautela. Testes com sangue deveriam ser realizados para verificar a influência das variações de pressão na hemólise.


OBJECTIVE: Among the equipments used in cardiopulmonary bypass the roller pumps have great importance with various models available from several manufacturers. The calibration is an important factor in hemolysis rates and its potential is different in each. Researchers do not always approach details on the pump bed profiles assuming that the standardized calibration settings ensure equal and comparable values for all models of roller pumps. We have mainly two methods for calibration of pumps which also interferes on the hemolytic potential. In both of them, the characteristics of fluid impulsion defined by the pump bed design are not considered. The aim of this study is to compare the hydrodynamic profile of three models of roller pumps available in the Brazilian market. METHODS: The rollers occlusion was performed by measures of drop and dynamic calibration. Two different silicone diameter tubes were used (3/8 x 1/16 and 1/2 x 3/32 inches). RESULTS: The profiles showed differences in their variances, P<0.01 for drop rate measures and P<0.0001 for dynamic calibration. Different changes in pressure were found between the pumps analyzed (P<0.002). CONCLUSION: The measures of occlusion are dependent on the design of the pump bed and comparisons involving roller pumps should be performed with caution. Blood tests should be performed to verify the influence of changes in hemolysis pressure.


Subject(s)
Cardiopulmonary Bypass/instrumentation , Pulsatile Flow/physiology , Analysis of Variance , Brazil , Calibration , Equipment Design , Linear Models
5.
Araraquara; s.n; 2008. 130 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: lil-590755

ABSTRACT

O objetivo dessa tese foi avaliar os efeitos da intrusão ortodôntica no processo de reparação de lesão de furca grau III em cães, e da presença de fator de necrose tumoral alfa (TNFα) e/ou interleucina-1 beta (IL-1ß) na mecanoresposta de células com característica de osteócitos e osteoblastos in vitro. No estudo in vivo, lesões de furca grau III foram criadas em pré-molares inferiores de sete cães. Após 75 dias, as lesões foram aleatoriamente tratadas com cirurgia a retalho (OFD) associada ou não à regeneração tecidual guiada (GTR) e enxerto ósseo autógeno (BA). Após um mês, iniciou-se a intrusão ortodôntica (I) em parte dos dentes tratados pelas duas diferentes abordagens (grupos teste), por meio de ancoragem em miniimplantes. Os cães foram sacrificados após três meses de movimentação e um mês de contenção. Todas as lesões de furca grau III foram reduzidas para grau II ou I nos grupos teste. O mesmo foi observado em 50% das lesões nos grupos controle (sem movimentação). O nível de inserção clínico foi reduzido nos grupos teste, no final da contenção (p<0.01). O grupo OFD+I apresentou maior preenchimento ósseo que os demais grupos (p<0.05), demonstrando superioridade desta associação, no tratamento de lesões de furca grau III, em cães. Esses resultados levantaram a hipótese de que o processo de degradação da membrana e/ou enxerto ósseo interagiria negativamente sobre o processo de reparo quando associado a forças ortodônticas, pois a presença de mediadores inflamatórios estaria intensificada. É conhecido que a alteração tecidual proveniente da movimentação ortodôntica é resultado da ação de mediadores químicos sobre as células dos tecidos periodontais. Portanto, buscamos avaliar in vitro a ação de duas citocinas pró-inflamatórias, TNFα e IL-1ß, sobre células ósseas em presença e ausência de carga mecânica.


The aim was to assess the effects of orthodontic intrusion on the healing of class III furcation lesions in dogs, and of the presence of tumor necrosis factor alpha (TNFα) and/or interleukin-1 beta (IL-1ß) on the mechanoresponse of osteocyte and osteoblast-like cells in vitro. In the in vivo study, class III furcation lesions were created in lower pre-molars of seven mongrel dogs. After 75 days, teeth were randomly treated with open flap debridment (OFD) associated or not to guided tissue regeneration (GTR) and bone autograft (BA). After one month, teeth were randomly assigned to orthodontic intrusion using mini-implants anchorage or no movement. Dogs were sacrificed after three months of movement and one month contention. All class III furcations were closed or reduced to class II or I lesions in the intrusion groups while 50% of the class III lesions in non-moved teeth remained unchanged. Clinical attachment level was reduced in the intrusion groups by the end of contention (p<0.01). OFD + I presented smaller soft tissues area and larger bone tissue area than other groups (p<0.05). Orthodontic intrusion with mini-implants anchorage improved healing of class III furcation defects after OFD in dogs. Based on these results we hypothesized that degradation of membrane and/or bone autograft can negatively interfere on repair when associated to orthodontic movement because inflammatory mediators are intensified. It‘s known that cytokines are present during orthodontic movement which are acting on periodontal cells. Therefore we evaluated in vitro the effects of two pro-inflammatory cytokines, TNFα and IL-1ß, on bone cells in presence or absence of mechanical loading.


Subject(s)
Cytokines , Furcation Defects , Guided Tissue Regeneration, Periodontal , Tooth Movement Techniques , Pulsatile Flow
6.
São Paulo; s.n; 2005. 59 p. ilus, graf, tab.
Thesis in Portuguese | LILACS | ID: lil-586992

ABSTRACT

Objetivo: Medir a pulsatilidade da parede do aneurisma de aorta humano antes e depois de sua correção endoluminal. Método: Cinco aneurismas foram submetidos à perfusão pulsátil antes e depois do implante de uma endoprótese. Resultado: o nível da coluna de água oscilou durante a pulsação com variações de 17, 16, 13, 7 e 25 cm antes da colocação da endoprótese. Depois da prótese, a oscilação diminuiu em todos os casos para 13, 12, 9, 3,5 e 23 cm, respectivamente. Conclusão: A pulsação da endoprótese é transmitida à parede do aneurisma.


Objective: To measure the pulsatility of human aortic aneurysms before and after exclusion with endograft. Method: Five aneurysms were submitted to pulsatile perfusion before and after implantation of a bifurcated endograft. Result: The level of the water column oscillated during pulsation, in each case, with an amplitude of 17, 16, 13, 7 and 25 cm before the endograft insertion. After that, the amplitudes dropped to, respectively 13, 12, 9, 3.5 and 23 cm.Conclusion: Pulsation of an endograft is transmitted to the aneurysm wall even in the absence of endoleak.


Subject(s)
Humans , Aortic Aneurysm/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation , Cadaver , Humans , Pulsatile Flow